Document

Suture Button versus Screw Fixation in Latarjet : A Systematic review

Description

Suture Button Fixation in Latarjet Has Similar Load to Failure and Clinical Outcomes but Lower Bone Resorption Compared With Screw Fixation: A Systematic Review

 

Purpose: To compare the 2 Latarjet fixation techniques screw fixation (SF) versus suture button (SB) for clinical, biomechanical, and radiologic outcomes. Methods: A systematic review was conducted in accordance with Preferred Reporting Items for Systematic and Meta-Analyses guidelines using MEDLINE and Embase databases and was prospectively registered on PROSPERO. Only comparative clinical and biomechanical studies of Latarjet with SF and SB were included. Studies were appraised using the Methodical Index for Non-Randomised Studies (MINORS) tool. Results: Eleven studies met eligible criteria: 7 clinical studies (SB, n = 279; SF, n = 845) and 4 biomechanical. In total, 80.9% (SB) and 84.2% (SF) of patients were male. Follow-up ranged from 6 to 63.6 months. The overall recurrent instability rate for SB ranged from 0 to 8.3% and for SF ranged from 0 to 2.75%. Only one study demonstrated a greater recurrent instability rate with SB (P= .02). Overall SB complication rates ranged from 0 to 12.5% and SF ranged from 0 to 27%. Two studies reported greater complications and reoperations with SF related to hardware. Summary forest plots from 4 studies showed no significant difference in Walch Duplay score, Rowe score and VAS for pain. There was no statistically significant difference between SB and SF in the postoperative range of motion. Radiologically, there was no significant difference in graft positioning and union at final follow-up, but graft resorption was greater in SF (range 25.2%-47.6%) compared with SB (range 10.1%-18.5%). Biomechanical studies showed no significant difference in maximum load to failure (SB, range 184-266 N vs SF, range 148-288 N). Conclusions: Clinically, SB fixation demonstrated similar functional outcome and range of motion when compared with SF, with the potential benefit of lower rates of graft resorption and hardware-related complications. Biomechanically there was no difference in maximum load to failure.

Content restricted!

You need to login to see this content or to become an ESSKA member.

Author

Nayeem Z Hali

Mr

Worcestershire Acute Hospitals NHS Trust, UK

Muaaz Tahir

Mr

The Royal Orthopaedic Hospital NHS Foundation Trust, UK

Robert W Jordan

Mr

University Birmingham Hospitals NHS Foundation Trust, UK

Hubert Laprus

Mr

St Luke's Hospital, Poland

Jarret Woodmass

Mr

Pan Am Clinic, Canada

Peter D' Alessandro

Mr

Orthopaedic Research Foundation of Western Australia, Australia

Shahbaz S Malik

Mr

Worcestershire Acute Hospitals NHS Trust, UK

Our Sponsors